Skip to content
Snippets Groups Projects
Commit 9aa2b9c1 authored by Anders Markvardsen's avatar Anders Markvardsen
Browse files

Some initial VESUVIO parameter files - in fact apart from the chance

of instrument name copies of the TOSCA param files. 

Adding these at least the indirect diffraction does not complain when
selecting VESUVIO as the instrument.

re #3443
parent 2c3479e7
No related branches found
No related tags found
No related merge requests found
<?xml version="1.0" encoding="UTF-8" ?>
<parameter-file instrument = "VESUVIO" date = "2011-07-28T00:00:00">
<component-link name = "VESUVIO">
<parameter name="deltaE-mode" type="string">
<value val="indirect"/>
</parameter>
<!-- These properties are neceessary for use in the Indirect CTE interface. -->
<parameter name="analysers" type="string">
<value val="graphite" />
</parameter>
<parameter name="refl-graphite" type="string">
<value val="002" />
</parameter>
<!-- This parameter will be taken as a default value for the rebinning of
the data in DeltaE. The existence of the parameter will make rebinning
the default, as opposed to not rebinning.
This is necessary so that the spectra can be grouped.
-->
<parameter name="rebin-default" type="string">
<value val="-2.5,0.015,3,-0.005,1000" />
</parameter>
<!-- Reduction workflow parameters under this line -->
<parameter name="Workflow.MonitorArea" >
<value val="5.391011e-5" />
</parameter>
<parameter name="Workflow.MonitorThickness" >
<value val="0.013" />
</parameter>
<parameter name="Workflow.MonitorScalingFactor">
<value val="1e9" />
</parameter>
<parameter name="Workflow.UnwrapMonitor" type="string">
<value val="Never" />
</parameter>
<parameter name="Workflow.ChopDataIfGreaterThan">
<value val="40000" />
</parameter>
<parameter name="Workflow.GroupingMethod" type="string">
<value val="Fixed" />
</parameter>
<parameter name="Workflow.FixedGrouping" type="string">
<value val="0-69,70-139" />
</parameter>
<parameter name="Workflow.Masking" type="string">
<value val="IdentifyNoisyDetectors" />
</parameter>
</component-link>
</parameter-file>
\ No newline at end of file
<?xml version="1.0" encoding="UTF-8" ?>
<parameter-file instrument = "VESUVIO" date = "2011-07-28T00:00:00">
<component-link name = "VESUVIO">
<parameter name="analysis-type" type="string">
<value val="diffraction" />
</parameter>
<parameter name="spectra-min">
<value val="146" />
</parameter>
<parameter name="spectra-max">
<value val="149" />
</parameter>
<parameter name="Workflow.Diffraction.Correction" type="string">
<value val="Monitor" />
</parameter>
<parameter name="Workflow.MonitorScalingFactor">
<value val="1" />
</parameter>
<!-- These two properties being set to invalid values (-1) will signal to the
reducer that it is not to correct for monitor efficiency.
-->
<parameter name="Workflow.MonitorArea">
<value val="-1" />
</parameter>
<parameter name="Workflow.MonitorThickness">
<value val="-1" />
</parameter>
</component-link>
</parameter-file>
\ No newline at end of file
<?xml version="1.0" encoding="UTF-8" ?>
<parameter-file instrument = "VESUVIO" date = "2011-07-28T00:00:00">
<component-link name = "VESUVIO">
<parameter name="analysis-type" type="string">
<value val="spectroscopy" />
</parameter>
<parameter name="spectra-min">
<value val="1" />
</parameter>
<parameter name="spectra-max">
<value val="140" />
</parameter>
<parameter name="efixed-val">
<value val="0" />
</parameter>
<parameter name="peak-start">
<value val="0" />
</parameter>
<parameter name="peak-end">
<value val="0" />
</parameter>
<parameter name="back-start">
<value val="0" />
</parameter>
<parameter name="back-end">
<value val="0" />
</parameter>
</component-link>
</parameter-file>
\ No newline at end of file
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment