......@@ -13,6 +13,7 @@ Diffraction Changes
Improvements
############
- SNAP instrument geometry updated to include downstream monitor.
- :ref:`LoadILLDiffraction <algm-LoadILLDiffraction>` will not flip the even-numbered tubes when using the calibrated data, since they are flipped already in the nexus files.
- :ref:`PowderDiffILLDetScanReduction <algm-PowderDiffILLDetScanReduction>` will scale the counts by 1M, when normalisation to monitor is requested, and it will also offer to enable/disable the tube alignment, and offer tube by tube reduction.
- :ref:`PowderDiffILLDetEffCorr <algm-PowderDiffILLDetEffCorr>` now offers to use the raw or calibrated data blocks in the nexus files.
......
......@@ -33,7 +33,7 @@
</component>
<type name="sample-position" is="SamplePos"/>
<!-- ressonance monitor pixel with events -->
<!--MONITORS-->
<idlist idname="Downstream_monitor">
<id val="-2"/>
</idlist>
......@@ -47,7 +47,6 @@
</component>
</type>
<!--MONITORS-->
<idlist idname="monitors">
<id val="-1"/>
</idlist>
......@@ -60,8 +59,7 @@
</component>
</type>
<!-- detector components -->
<!--DETECTORS-->
<component type="East">
<location >
<parameter name="roty">
......