Skip to content
GitLab
Explore
Sign in
Primary navigation
Search or go to…
Project
mantid
Manage
Activity
Members
Labels
Plan
Wiki
Code
Merge requests
Repository
Branches
Commits
Tags
Repository graph
Compare revisions
Locked files
Deploy
Releases
Model registry
Analyze
Value stream analytics
Contributor analytics
Repository analytics
Code review analytics
Model experiments
Help
Help
Support
GitLab documentation
Compare GitLab plans
Community forum
Contribute to GitLab
Provide feedback
Keyboard shortcuts
?
Snippets
Groups
Projects
Show more breadcrumbs
mantidproject
mantid
Commits
48840e24
Commit
48840e24
authored
5 years ago
by
Harriet Brown
Browse files
Options
Downloads
Patches
Plain Diff
Add run numbers to test doc that can be run from archive
parent
85879664
No related branches found
No related tags found
No related merge requests found
Changes
1
Hide whitespace changes
Inline
Side-by-side
Showing
1 changed file
docs/source/interfaces/Engineering Diffraction Test Guide.rst
+7
-5
7 additions, 5 deletions
.../source/interfaces/Engineering Diffraction Test Guide.rst
with
7 additions
and
5 deletions
docs/source/interfaces/Engineering Diffraction Test Guide.rst
+
7
−
5
View file @
48840e24
...
...
@@ -14,6 +14,8 @@ it is recommended they read :ref:`Engineering_Diffraction-ref` instead which is
The files used in the following examples are found within System test files within
`<MantidBuildDir>/ExternalData/Testing/Data/SystemTest` after building the *SystemTestData* target.
Runs can also be loaded from the archive, however differen run numbers will be needed as older runs may
be deleted.
Overview
^^^^^^^^
...
...
@@ -39,9 +41,9 @@ If a vanadium calibration has never been run the `Current calibration` will be e
a calibration has been run these fields will retain their values for future runs of the program.
The following files can be used for the calibration run.
- *Vanadium#*: ENGINX00236516.nxs
- *Vanadium#*: ENGINX00236516.nxs
/ 307521 for archive
- *Calibration#*: ENGINX00241391.nxs
- *Calibration#*: ENGINX00241391.nxs
/ 305738 for archive
Once the calibration has completed if the calibration was successful plotting the spectra of the
newly created workspaces will produce images similar to below:
...
...
@@ -78,8 +80,8 @@ If the data is captured in event mode (i.e.. Event workspaces) it will first
need :ref:`preProcessing-Engineering_Diffraction_test-ref` .
A .nxs file containing histogram data needs to be selected for example *ENGINX00193749.nxs*
this can have all banks summed, specific spectra and list or use a
detector grouping to create
a texture.
/ 305761 on archive
this can have all banks summed, specific spectra and list or use a
detector grouping to create
a texture.
Once the focus run has finished it will save a focused .nxs file in
...
...
@@ -121,7 +123,7 @@ workspace with TOF as the X axis.
If the multi-period data with pulse times is captured `Multi-period data` should be used instead
with the delta in time on every step of the X axis entered.
For testing purposes with regular time binning testing should be done using
a .s0 file such as 299735.s08
,
For testing purposes with regular time binning testing should be done using
305761 on archive
,
multi-period data should instead use a run from 285643-285701 which are event workspaces.
Fitting
...
...
This diff is collapsed.
Click to expand it.
Preview
0%
Loading
Try again
or
attach a new file
.
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Save comment
Cancel
Please
register
or
sign in
to comment