#pylint: disable=no-init,invalid-name
import stresstesting
from mantid.simpleapi import *
from reduction_workflow.instruments.sans.sns_command_interface import *
from mantid.api import *
import os

class EQSANSNormalisationNoFlux(stresstesting.MantidStressTest):
    """
        Analysis Tests for EQSANS
        Testing that the I(Q) output of is correct
    def runTest(self):
        """
            Check that EQSANSTofStructure returns the correct workspace
        """
        configI = ConfigService.Instance()
        configI["facilityName"]='SNS'
        ws = "__eqsans_normalisation_test"

        EQSANSLoad(Filename="EQSANS_1466_event.nxs", OutputWorkspace=ws,
                   PreserveEvents=False, LoadMonitors=False)
        EQSANSNormalise(InputWorkspace=ws, NormaliseToBeam=False,
                        OutputWorkspace=ws)
        SumSpectra(InputWorkspace=ws, OutputWorkspace="eqsans_no_flux")
    def validate(self):
        self.disableChecking.append('Instrument')
        self.disableChecking.append('Sample')
        self.disableChecking.append('SpectraMap')
        self.disableChecking.append('Axes')
        return "eqsans_no_flux", 'EQSANSNormalisation_NoFlux.nxs'

class EQSANSNormalisationDefault(stresstesting.MantidStressTest):
    """
        Analysis Tests for EQSANS
        Testing that the I(Q) output of is correct
    def runTest(self):
        """
            Check that EQSANSTofStructure returns the correct workspace
        """
        configI = ConfigService.Instance()
        configI["facilityName"]='SNS'
        ws = "__eqsans_normalisation_test"

        EQSANSLoad(Filename="EQSANS_1466_event.nxs", OutputWorkspace=ws,
                   PreserveEvents=False, LoadMonitors=False)
        EQSANSNormalise(InputWorkspace=ws,NormaliseToBeam=True,
                        OutputWorkspace=ws)
        SumSpectra(InputWorkspace=ws, OutputWorkspace="eqsans_default_flux")
    def validate(self):
        # This test only makes sense if /SNS is not available,
        # otherwise we will end up using the actual beam file,
        # which may not produce the same output. This test
        # is meant to exercise the functionality to find the
        # beam profile and will only produce the correct results
        # on a system that is not hooked up to real instrument files.
        if os.path.isdir('/SNS/EQSANS'):
            return True
        self.disableChecking.append('Instrument')
        self.disableChecking.append('Sample')
        self.disableChecking.append('SpectraMap')
        self.disableChecking.append('Axes')
        return "eqsans_default_flux", 'EQSANSNormalisation_DefaultFlux.nxs'
class EQSANSNormalisationInputFlux(stresstesting.MantidStressTest):
    """
        Analysis Tests for EQSANS
        Testing that the I(Q) output of is correct
    def runTest(self):
        """
            Check that EQSANSTofStructure returns the correct workspace
        """
        configI = ConfigService.Instance()
        configI["facilityName"]='SNS'
        ws = "__eqsans_normalisation_test"
        spectrum_file = "eqsans_beam_flux.txt"

        EQSANSLoad(Filename="EQSANS_1466_event.nxs", OutputWorkspace=ws,
                   PreserveEvents=False, LoadMonitors=False)
        EQSANSNormalise(InputWorkspace=ws,NormaliseToBeam=True,
                        BeamSpectrumFile=spectrum_file,
                        OutputWorkspace=ws)
        SumSpectra(InputWorkspace=ws, OutputWorkspace="eqsans_input_flux")
    def validate(self):
        self.disableChecking.append('Instrument')
        self.disableChecking.append('Sample')
        self.disableChecking.append('SpectraMap')
        self.disableChecking.append('Axes')
        return "eqsans_input_flux", 'EQSANSNormalisation_InputFlux.nxs'

class EQSANSNormalisationBeamFlux(stresstesting.MantidStressTest):
    """
        Analysis Tests for EQSANS
    """
    data_ws=""
    prop_mng=""
    def runTest(self):
        """
            Check that EQSANSTofStructure returns the correct workspace
        """
        configI = ConfigService.Instance()
        configI["facilityName"]='SNS'
        self.prop_mng = "eqsans_normalise_options"
        self.data_ws = "eqsans_normalise_data_ws"

        EQSANSLoad(Filename="EQSANS_3293_event.nxs",
                   NoBeamCenter=True,
                   ReductionProperties=self.prop_mng,
                   OutputWorkspace=self.data_ws)
        EQSANSNormalise(InputWorkspace=self.data_ws,
                        BeamSpectrumFile='SANSBeamFluxCorrectionMonitor.nxs',
                        NormaliseToMonitor=True,
                        ReductionProperties=self.prop_mng,
                        OutputWorkspace=self.data_ws)

    def validate(self):
        ref_values = [9.66631788e-08, 1.99540011e-08, 0.00000000e+00, 2.84897084e-08,
                      2.58802935e-08, 0.00000000e+00, 3.43023370e-08, 1.11017160e-08,
                      3.22199520e-08, 8.31598470e-08, 3.05866692e-08, 3.00540473e-08,
                      2.97218143e-08, 5.92981344e-08, 2.92735276e-08, 1.91616696e-08,
                      4.63637972e-08, 8.94602703e-09, 4.34305480e-08, 1.71487695e-08,
                      2.51816301e-08, 3.24283000e-08, 2.40811371e-08, 3.20081242e-08,
                      8.03994116e-09, 3.23002602e-08, 2.43204630e-08, 7.99166600e-09,
                      2.40009985e-08, 8.04082934e-09, 1.61818559e-08, 2.44975746e-08,
                      0.00000000e+00, 2.49096583e-08, 0.00000000e+00, 8.48764614e-09,
                      8.59073435e-09, 0.00000000e+00, 8.77853612e-09, 0.00000000e+00,
                      3.69158961e-08, 2.16789982e-08, 1.41834793e-08]
        output_y = mtd[self.data_ws].readY(0)
        if output_y[0]-ref_values[0] > 0.000006:
            return False
        if output_y[5]-ref_values[5] > 0.000006:
            return False
        if output_y[10]-ref_values[10] > 0.000006:
            return False
        if output_y[25]-ref_values[25] > 0.000006:
            return False