from __future__ import (absolute_import, division, print_function)
import stresstesting
import mantid.simpleapi as mantid
from mantid import config
from isis_powder import polaris
DIRS = config['datasearch.directories'].split(';')
class isis_powder_PolarisVanadiumCalTest(stresstesting.MantidStressTest):
def requiredFiles(self):
return _gen_required_files()
def runTest(self):
self.calibration_results = _run_vanadium_calibration()
def validate(self):
return _calibration_validation(self, self.calibration_results)
def cleanup(self):
# TODO clean up reference files properly
_clean_up()
class isis_powder_PolarisFocusTest(stresstesting.MantidStressTest):
focus_results = None
def requiredFiles(self):
return _gen_required_files()
def runTest(self):
# Gen vanadium calibration first
_run_vanadium_calibration()
self.focus_results = _run_focus()
def validation(self):
return _calibration_validation(self, self.focus_results)
def cleanup(self):
pass
# TODO
def _gen_required_files():
input_files = ["POLARIS/POL78338.raw",
"POLARIS/POL78339.raw",
"POLARIS/POL79514.raw"]
return input_files
def _run_vanadium_calibration():
vanadium_run = 78338
empty_run = 78339
output_file_name = _get_calibration_output_name()
gen_absorb = True
polaris_obj = setup_polaris_instrument()
# Try it without an output name
polaris_obj.create_calibration_vanadium(vanadium_runs=vanadium_run, empty_runs=empty_run,
gen_absorb_correction=gen_absorb)
return polaris_obj.create_calibration_vanadium(vanadium_runs=vanadium_run, empty_runs=empty_run,
output_file_name=output_file_name, gen_absorb_correction=gen_absorb)
def _run_focus():
run_number = 79514
polaris_obj = setup_polaris_instrument()
return polaris_obj.focus(run_number=run_number, focus_mode="")
def _calibration_validation(cls, results):
_validation_setup(cls)
output_full_path = os.path.join(_get_calibration_dir(), _get_calibration_output_name())
ws_to_validate_output_name = "pearl_van_cal_output"
mantid.LoadNexus(Filename=output_full_path, OutputWorkspace=ws_to_validate_output_name)
reference_file_name = "POLARIS_PowderDiffVanCalibration.nxs"
return ws_to_validate_output_name, reference_file_name
def _focus_validation(cls, results):
_validation_setup(cls)
reference_file_name = "POLARIS_PowderFocus79514.nxs"
focus_output_name = "Focus_results"
mantid.GroupWorkspaces(InputWorkspaces=results, OutputWorkspace=focus_output_name)
return focus_output_name, reference_file_name
def _validation_setup(cls):
cls.disableChecking.append('Instrument')
cls.disableChecking.append('Sample')
cls.disableChecking.append('SpectraMap')
def _clean_up():
output_file_path = _get_calibration_dir() + _get_calibration_output_name()
try:
os.remove(output_file_path)
except OSError:
print ("Could not delete output file at: ", output_file_path)
def setup_polaris_instrument():
user_name = "Test"
calibration_dir = _get_calibration_dir()
raw_data_dir = os.path.join(DIRS[0], "POLARIS")
output_dir = _get_output_dir()
polaris_obj = polaris.Polaris(user_name=user_name, calibration_dir=calibration_dir, raw_data_dir=raw_data_dir,
output_dir=output_dir)
return polaris_obj
def _get_calibration_output_name():
return "system_test_polaris_van_cal.nxs"
def _get_output_dir():
return os.path.join(DIRS[0], "POLARIS/DataOut")
def _get_calibration_dir():
return os.path.join(DIRS[0], "POLARIS/test/Cycle_15_2/Calibration")