#pylint: disable=no-init
from mantid.simpleapi import *
from mantid.api import *
from mantid.kernel import *
from mantid import config
def _get_instrument_property_list(instrument, property_name):
    """
    Gets a list of properties from an instrument string property.

    @param instrument Instrument object
    @param property_name Name of property
    @return A list of string values
    """

    raw_property_list = instrument.getStringParameter(property_name)
    if raw_property_list is None or len(raw_property_list) == 0:
        raise RuntimeError('Got empty list for parameter %s' % property_name)

    property_list = raw_property_list[0].split(',')

    return property_list


class IndirectTransmission(PythonAlgorithm):
        return "Workflow\\MIDAS;PythonAlgorithms"

        return "Calculates the scattering & transmission for Indirect Geometry spectrometers."

        self.declareProperty(name='Instrument', defaultValue='IRIS',
                             validator=StringListValidator(['IRIS', 'OSIRIS', 'TOSCA', 'BASIS', 'VISION']),
                             doc='Instrument')

        self.declareProperty(name='Analyser', defaultValue='graphite',
                             validator=StringListValidator(['graphite', 'mica', 'fmica', 'silicon']),
                             doc='Analyser')

        self.declareProperty(name='Reflection', defaultValue='002',
                             validator=StringListValidator(['002', '004', '006', '111']),
                             doc='Reflection')

        self.declareProperty(name='ChemicalFormula', defaultValue='', validator=StringMandatoryValidator(),
                             doc='Sample chemical formula')

        self.declareProperty(name='NumberDensity', defaultValue=0.1,
                             doc='Number denisty (atoms/Angstrom^3). Default=0.1')

        self.declareProperty(name='Thickness', defaultValue=0.1,
                             doc='Sample thickness (cm). Default=0.1')

        self.declareProperty(WorkspaceProperty('OutputWorkspace', "", Direction.Output),
                             doc="The name of the output workspace.")


    def PyExec(self):
        instrument_name = self.getPropertyValue('Instrument')
        analyser = self.getPropertyValue('Analyser')
        reflection = self.getPropertyValue('Reflection')
        formula = self.getPropertyValue('ChemicalFormula')
        density = self.getPropertyValue('NumberDensity')
        thickness = self.getPropertyValue('Thickness')
        # Create an empty instrument workspace
        workspace = '__empty_' + instrument_name
        CreateSimulationWorkspace(OutputWorkspace=workspace,
                                  Instrument=instrument_name,
                                  BinParams='0,0.5,1')
        # Do some validation on the analyser and reflection
        instrument = mtd[workspace].getInstrument()
        valid_analysers = _get_instrument_property_list(instrument, 'analysers')
        logger.debug('Valid analysers for instrument %s: %s' % (instrument_name, str(valid_analysers)))

        # Check the analyser is valid for the instrument
        if analyser not in valid_analysers:
            # Remove idf/ipf workspace
            DeleteWorkspace(workspace)
            raise RuntimeError('Analyser %s not valid for instrument %s' % (analyser, instrument_name))
        else:
            # If the analyser was valid then we can check the reflection
            reflections_param_name = 'refl-%s' % analyser
            valid_reflections = _get_instrument_property_list(instrument, reflections_param_name)
            logger.debug('Valid reflections for analyser %s: %s' % (analyser, str(valid_reflections)))

            if reflection not in valid_reflections:
                # Remove idf/ipf workspace
                DeleteWorkspace(workspace)
                raise RuntimeError('Reflection %s not valid for analyser %s on instrument %s' % (reflection, analyser, instrument_name))
        # Load instrument parameter file
        idf_directory = config['instrumentDefinition.directory']
        name_stem = instrument_name + '_' + analyser + '_' + reflection
        ipf_filename = idf_directory + name_stem + '_Parameters.xml'
        LoadParameterFile(Workspace=workspace, Filename=ipf_filename)
        # Get efixed value
        efixed = self._get_efixed(workspace)
        logger.notice('Analyser : ' + analyser + reflection + ' with energy = ' + str(efixed))
        result = SetSampleMaterial(InputWorkspace=workspace, ChemicalFormula=formula)
        # Elastic wavelength
        wave = 1.8 * math.sqrt(25.2429 / efixed)
        absorption_x_section = result[5] * wave / 1.7982
        coherent_x_section = result[4]
        incoherent_x_section = result[3]
        scattering_s_section = incoherent_x_section + coherent_x_section
        thickness = float(thickness)
        density = float(density)
        total_x_section = absorption_x_section + scattering_s_section
        transmission = math.exp(-density * total_x_section * thickness)
        scattering = 1.0 - math.exp(-density * scattering_s_section * thickness)
        # Create table workspace to store calculations
        table_ws = self.getPropertyValue('OutputWorkspace')
        table_ws = CreateEmptyTableWorkspace(OutputWorkspace=table_ws)
        table_ws.addColumn("str", "Name")
        table_ws.addColumn("double", "Value")
        # Names for each of the output values
        output_names = ['Wavelength', 'Absorption Xsection', 'Coherent Xsection', 'Incoherent Xsection',
                        'Total scattering Xsection', 'Number density', 'Thickness', 'Transmission (abs+scatt)', 'Total scattering']
        # List of the calculated values
        output_values = [wave, absorption_x_section, coherent_x_section, incoherent_x_section,
                         scattering_s_section, density, thickness, transmission, scattering]
        # Build table of values
        for data in zip(output_names, output_values):
            table_ws.addRow(list(data))
            logger.information(': '.join(map(str, list(data))))
        # Remove idf/ipf workspace
        DeleteWorkspace(workspace)
        self.setProperty("OutputWorkspace", table_ws)
    def _get_efixed(self, workspace):
        Gets an efixed value form a workspace.
        @param workspace Name of workspace to extract from
        @return Fixed energy value
        ws = mtd[workspace]

        # Try to get efixed from the parameters first
        try:
            instrument = ws.getInstrument()
            efixed = instrument.getNumberParameter('efixed-val')[0]
        except IndexError:
            efixed = 0.0

        # If that fails then get it by taking from group of all detectors
        if efixed == 0.0:
            spectra_list = range(0, ws.getNumberHistograms())
            GroupDetectors(InputWorkspace=workspace,
                           OutputWorkspace=workspace,
                           SpectraList=spectra_list)
            ws = mtd[workspace]
            det = ws.getDetector(0)
            efixed = mtd[workspace].getEFixed(det.getID())

        return efixed