Capability 1233: [QUICKNXS] Add the capability to reduce two samples from the same run

(EWM1233)

SUMMARY

BL-4A often measures two samples at the same time, with the signal for each sample covering two distinct area of the detector. IS would like to be able to extend the data reduction to be able to deal with this mode. Quicknxs would have to be changed to recognize two ROIs on the detector, and plot both reduced curves. Users would have to be able to change the peak selection.

Example: IPTS-31954 contains several runs showing two peaks in the Y-X plot of QuickNXS. See for instance this snapshot showing run 42536

REQUIREMENTS

  • New Data tabs will be included in the tabwidget. Each tab will zero in a particular peak. See a mockup of two Data tabs, one for each peak. Notice that each tab can have a different number of runs. In the mockup example, one tab has two runs and the other tab has one run.
  • When User presses "Reduce", reduction will proceed separately for each Data tab.

DESIGN

Run 42536

Two tabs, one for each peak

One Data tab in the GUI

Three Data tabs in the GUI

User presses "+" to add a new Data tab

Peak index in file naming convention

Edited by Borreguero Calvo, Jose