@@ -61,7 +61,7 @@ This model can be selected in the configuration file via the parameter `multipli

### Optimized parameters

An optimized parametrization of the Massey model based on measurements with an infrared lased TCT setup is implemented in Allpix Squared, based on Table 2 of \[[@rd50ionization]\] with the values:
An optimized parametrization of the Massey model based on measurements with an infrared laser is implemented in Allpix Squared, based on Table 2 of \[[@rd50ionization]\] with the values:

```math
\begin{aligned}
@@ -103,10 +103,10 @@ Temperature scaling of the ionization coefficient is performed via the $`\gamma(
Sentaurus TCAD user manual as:

```math
\gamma (T) = \tanh \left(\frac{\hbar \omega_{op}}{2 \times 8.6173\times 10^{-5} \,\text{eV/K} \cdot T_0} \right) \cdot \tanh \left(\frac{\hbar \omega_{op}}{2 \times 8.6173\times 10^{-5} \,\text{eV/K} \cdot T} \right)^{-1}
\gamma (T) = \tanh \left(\frac{\hbar \omega_{op}}{2 k_{\mathrm{B}} \cdot T_0} \right) \cdot \tanh \left(\frac{\hbar \omega_{op}}{2 k_{\mathrm{B}} \cdot T} \right)^{-1}
```

with $`\hbar \omega_{op} = 0.063 \,\text{eV}`$. The value of the reference temperature $`T_0`$ is not entirely clear as it is never
with $`\hbar \omega_{op} = 0.063 \,\text{eV}`$ and the Boltzmann constant $`k_{\mathrm{B}} = 8.6173\times 10^{-5} \,\text{eV/K}`$. The value of the reference temperature $`T_0`$ is not entirely clear as it is never
stated explicitly, a value of $`T_0 = 300 \,\text{K}`$ is assumed.

### Original publication
@@ -132,7 +132,7 @@ This model can be selected in the configuration file via the parameter `multipli

### Optimized parameters

An optimized parametrization of the Van Overstraeten-De Man model based on measurements with an infrared lased TCT setup is implemented in Allpix Squared, based on Table 3 of \[[@rd50ionization]\] with the following parameter values:
An optimized parametrization of the Van Overstraeten-De Man model based on measurements with an infrared laser is implemented in Allpix Squared, based on Table 3 of \[[@rd50ionization]\] with the following parameter values:

```math
\begin{aligned}
@@ -142,11 +142,12 @@ An optimized parametrization of the Van Overstraeten-De Man model based on measu
    a_{\infty, h} &= 2.519\times 10^{6} \,\text{/cm}\\
    b_{h} &= 2.428\times 10^{6} \,\text{V/cm}\\
    \\
    \hbar \omega_{op} = 0.0758 \,\text{eV}
    \hbar \omega_{op} &= 0.0758 \,\text{eV}
\end{aligned}
```

In contrast to the original model, this publication uses a parametrization without differentiating between low and high field regions.
In contrast to the original model, this publication uses a parametrization without differentiating between low and high field regions, hence only one parameter value is provided for each of $`a_{\infty, h}`$ and $`b_{h}`$.

This model can be selected in the configuration file via the parameter `multiplication_model = "overstraeten_optimized"`.


@@ -192,7 +193,7 @@ This model can be selected in the configuration file via the parameter `multipli

### Optimized parameters

An optimized parametrization of the Okuto-Crowell model based on measurements with an infrared lased TCT setup is implemented in Allpix Squared, based on Table 4 of \[[@rd50ionization]\] with the following parameter values:
An optimized parametrization of the Okuto-Crowell model based on measurements with an infrared laser is implemented in Allpix Squared, based on Table 4 of \[[@rd50ionization]\] with the following parameter values:

```math
\begin{aligned}